Parameter |
Description |
<GenericSensor> |
The MRPT CGenericSensor parameters |
decayValue |
Decay value(%) in the "active chamber" readings required in the Adaptive switching mode, to consider that a decay phase is starting.(maxValue - maxValue*decayValue/100.0 ) |
delay |
Delay to introduce to the gas readings as consequence of the pneumatic circuit and electronics (seconds) |
min_diff |
Minimum difference (value) that must exists between the readings of the actual active chamber (AC) and the candidate Chamber to switch at, to allow switching. |
minActiveTime |
Minimum time (seconds) a chamber must be active (odor flooded). In periodic Switching (strategy = 1) this is the Period. |
num_chambers |
The number of chambers in the e-nose device (see the OpenMORA wiki for more info) |
num_sensors_chamber |
The number of gas sensors to be read on each chamber. |
sensorID |
The sensor type (0x2620, 0x2601, etc) to be taken into account for the switching strategy. If sensorID = 0 the mean of all sensors is considered. |
strategy |
The MCE-nose Switching strategy: 0(No Switching), 1(Periodic Switching), 2(Adaptive), 3(Calibration), 4(Dual mode). (see the OpenMORA wiki for more info) |